Solar Tracking System
HB-D828
|
Single-axis solar trackers follow the sun from sunrise to sunset as it moves in the sky through the day from east to west. They are called a single-axis trackers as the mechanism only rotates in one plane around a single axis. The axis can be oriented so that the cells stand up at a tilt (called a polar axis) or lie flat (called a horizontal axis). Horizontal axis' are more suitable for small latitudes , whilst polar axis are more suitable for larger latitudes. |
Dual-axis, or two-axis, trackers follow the sun completely. The two axes of rotation allow the tracker to position the solar cells directly perpendicular to the sun's ray all the time. As they are able to adjust for the sun's height as well east to west rotation dual-axis trackers fully adjust for seasons as well as adjusting to face the sun as it sits low in the horizon at sunrise and sunset, and high in the sky in the middle of the day. |
|
Linear Actuator for Solar Tracker
The solar product range has been designed with all challenges like limited end play, high precision, large holding forces due to wind loads etc. Our design criteria have been to design actuators with a lifetime of 20 years.
Specifications
• Max thrust up to 15,000 N
• Max speed up to 3 mm/sec
• Standard stroke 50 - 1200 mm
• Protection class IP66
• Voltage 24V DC
• Aluminum housing, Stainless-steel rod
• Integrated brake, high self-locking ability
• Built-in end stop and hall sensor feedback systems
• Salt spray and chemical tested
• Working temperature -40ºC to +70ºC
• Small full-load-current
Dimension drawing of linear actuator
Detailed drawing will be offered based on client's requirement.
Robust and dependable
waterproof and dustproof test
Test |
Details |
Static load |
Static push and pull tests of basic actuators with 300, 800 and 1000 mm strokes. |
Dynamic load |
Dynamic push/pull tests of the actuator. |
Self-locking |
Self locking tests at dynamic and static load. |
Lifetime |
Lifetime tests performed at combined loads in push and pull situations. |
Climate test A |
Actuators are tested with 12000N load, at temperatures of plus 5 °C and plus 40°C. |
Climate test B |
Actuators are tested with 12,000N load, at temperatures of minus 40 °C and plus 70°C. |
Current and Speed |
Actuators with loads of 0N, 8,000N and 12,000N are tested at minus 40°C, plus 30°C and 70°C. |
IP X6 static |
Actuators are tested for water ingress according to IP X6, without movement. |
IP 6X |
Actuators are tested for dust sealing properties according to IP 6X. |
Salt spray test |
Actuators are tested for corrosion resistance at 500 hours salt spray test. |
UVI test |
Actuators housing and cable are tested for UVI resistance ability. |